How A Four-Point Contact Ball Slewing Bearing Carries Loads

News Article 1700

A single-row four-point contact ball slewing bearing uses one row of steel balls to carry axial loads in either direction. The inner and outer raceways each offer two possible contact locations, forming two diagonal load paths. Reverse the axial load and the other diagonal pair takes over. This geometry also lets one bearing carry axial force, radial force, and overturning moment together. NREL DG03 Design Guide, Chapter 2, Figure 1

Cutaway of a gearless four-point contact ball slewing bearing showing one row of steel balls
A cutaway illustration of a gearless slewing bearing with one row of steel balls between the inner and outer rings.

How Four Contact Points Form Two Load Paths

In a radial cross-section, each ring’s raceway is formed by two circular arcs. This profile is called a Gothic arch. In a bearing with positive clearance under a purely axial load, one ring shifts relative to the other until the ball bears against one flank of the inner raceway and the diagonally opposite flank of the outer raceway. When the axial load reverses, the other pair carries it. Which of the four possible locations actually carry load depends on the applied loads, internal clearance or preload, and ring deformation. NREL Raceway Cross-Section · Study Of Load Distribution In Four-Point Contact Slewing Bearings

Each contact force acts at an angle, so it has both axial and radial components. On a horizontal turntable, a centered vertical load acts along the rotation axis. Add a horizontal side force and the rings shift radially relative to each other. Some balls carry more load while others unload. The load on the most heavily loaded ball can therefore change even when the axial force stays the same. Four-Point Contact Slewing Bearing Static Load Model, Section 2

Why The Same Weight Is Harder To Support Off Center

Consider a stationary horizontal turntable. A workpiece exerts a downward force of 20 kN. Ignoring the weight of the table and other external forces, placing the workpiece’s center of gravity 0.5 m from the rotation axis produces an axial force of 20 kN and an overturning moment of 10 kN·m. Move the workpiece to 1.5 m from the axis and the axial force stays at 20 kN. The moment triples to 30 kN·m.

The moment tilts one ring relative to the other. One diagonal contact pair carries more load on one side of the bearing and unloads on the opposite side. If the moment is large enough, the other diagonal pair can engage on that opposite side. Balls in the same row can then transmit opposing axial reactions in different parts of the circumference to resist the tilt. Four-Point Contact Slewing Bearing Static Load Model, Section 2

How To Read The Static Load Curve

For each load case, express the axial force Fa, radial force Fr, and overturning moment M at the reference point specified in the bearing documentation. The two turntable cases above both have an axial force of 20 kN and zero radial force. On a chart of axial force versus overturning moment, the 10 kN·m and 30 kN·m cases plot at different points. The first may fall in the allowable region while the second falls outside it. Four-Point Contact Slewing Bearing Static Load Capacity Study, Figure 2

When radial force is present, check the chart notes. Some curves plot axial force and specify the radial loads for which the curve applies. Others plot an equivalent axial load, calculated from the axial and radial forces using the method given for that model. The load case passes the static check represented by the curve if it meets the chart’s conditions and falls within the marked allowable region. For a case outside those conditions, obtain a combined-load assessment for that bearing. Four-Point Contact Slewing Bearing Static Load Capacity Study, Sections 1–2

Why The Mounting Flanges And Bolts Also Need A Check

The mounting flanges and bolts transfer the bearing loads to the machine frame. If flange stiffness varies around the circumference, the rings can deform with the supporting structure and concentrate load on a few balls. Insufficient bolt preload can also let the flange joint open locally under an overturning load. Check the mounting and bolt assumptions that apply to the static load curve. If the installation falls outside those assumptions, include flange stiffness, bolt preload, and joint contact in the assembly assessment. NREL DG03 Design Guide, Sections 3.2.8–3.2.10 And 4.4–4.6

The prev: The next: